Automatic Calculation
Some items in the measurement menu are automatically calculated based on measurements of other
items.
HC
This is automatically calculated using the following formula, provided there are measured BPD and
OFD values.
Exception: when you use Merz reference,
AC
This is automatically calculated using the following formula, provided there are measured APD and
TAD values.
Exception: when you use Merz reference,
FTA
This is automatically calculated using the following formula, provided there are measured APD and
TAD values.
ThC
This is automatically calculated using the following formula, provided there are measured APTD
and TTD values.