13-350 | OWNER’S GUIDE
Sensor connection
Standard charge accelerometer or microphone connector and cable. Use a standard BNC plug on the
Dewetron module side. The sensor side may be molded into the sensor, or a modular connector with BNC,
10-32, etc.
BNC to Microdot adapter
This adapter is available as an option with the DAQP-CHARGE-B module.
High pass lter
The time constant of the internal highpass lter depends on the used input range. For range 1 (100 pC, 500
pC and 2,000 pC) the time constant is 2 seconds (or 0.07 Hz), for range 2 (10,000 pC and 40,000 pC) the
time constant is 40 seconds (or 3.9 mHz). For the highest both ranges (200,000 pC and 1,000,000 pC) the
time constant is 1,000 seconds or 0.16 mHz).