- 29 -
[PROTOCOL SETTING]
SW704(0:
↓
,1:
↑
)
Protocol HALF/FULL
1 2 3 4
0000 SAMSUNG HALF
1000 SAMSUNG FULL
0100 VICON HALF
1100 PANASONIC HALF
0010 PANASONIC FULL
0110 AD FULL
1110 PHILIPS HALF
0001 PELCO-P HALF
1001 KALATEL HALF
0101 ERNA HALF
1101 DIAMOND HALF
0011 VCLTP HALF
1011 PELCO-D HALF
0111 PELCO-D FULL
1111 VICON FULL
[BAUD-RATE SETTING]
1. SAMSUNG 2. VICON
Baud Rate SW704-5 SW704-6
38400BPS OFF OFF
19200BPS ON OFF
9600BPS OFF ON
4800BPS ON ON
Baud Rate SW704-5 SW704-6
19200BPS OFF OFF
9600BPS ON OFF
4800BPS OFF ON
600BPS ON ON
3. PHILIPS 4. PANASONIC, PELCO-P
Baud Rate SW704-5 SW704-6
38400BPS OFF OFF
9600BPS ON OFF
2400BPS OFF ON
1200BPS ON ON
Baud Rate SW704-5 SW704-6
19200BPS OFF OFF
9600BPS ON OFF
4800BPS OFF ON
2400BPS ON ON
5. DIAMOND,VCLTP 6. ERNA, PELCO-D
Baud Rate SW704-5 SW704-6
9600BPS OFF ON
Baud Rate SW704-5 SW704-6
2400BPS ON ON
(
※
Only 9600BPS is supported.) (
※
Only 2400BPS is supported.)
7. KALATEL 8. AD
Baud Rate SW704-5 SW704-6
9600BPS OFF ON
4800BPS ON ON
Baud Rate SW704-5 SW704-6
9600BPS OFF OFF
4800BPS ON OFF
2400BPS OFF ON
1200BPS ON ON
[ADDRESS SETTING]
:
Use SW704. (Refer to SCC-C64XX User's Manual.)