1) If door is open, door S/W contact is closed. Then MICOM receives low signal and detects
door open then, Relay control circuit receives HIGH signal and turn Lamp on.
2) If door is closed, door S/W contact is open. Then MICOM receives high signal and detects
door close then, Relay control circuit receives LOW signal and turn Lamp off.
DOOR
F
R
Door Conditions
CLOSE
OPEN
CLOSE
OPEN
Door S/W Contact
OPEN
CLOSE
OPEN
CLOSE
MICOM
PIN NO
# 39
# 40
Micom Input Voltage
HIGH
LOW
HIGH
LOW
6-5. Temperature Sensor
1) The sensor uses the characteristics of thermistor. If temperature goes higher, resistance goes
lower. On the contrary, if temperature goes lower, resistance goes higher.
2) MICOM input voltage is counted by sensor as follows.
(V
CC : 5V, RTH : Sensor reisitance)
3) For the resistance information on temperature and MICOM input voltage, please refer the
conversion table. (Page. 41)
RTH
VF = X Vcc
RTH + R301
When Sensor is open
MICOM input HIGH
When sensor is cut off
MICOM input LOW
( Air Sensor)