6-4 Fault Diagnosis of Major Parts
Indoor "Temp.Sensor"
Indoor "Heat ex. Sensor"
Outdoor "Temp.Sensor"
Outdoor "Deice Temp. Sensor"
Outdoor "Discharge
Temp.Sensor"
Outdoor "OLP Temp.Sensor"
Indoor Fan Motor
Outdoor Fan Motor
Stepping Motor
Measure resistance with a tester.
Normal
Abnormal , 0 open or short
Normal
Abnormal , 0 open or short
Measure the resistance between terminals of the connector(CN72) with a tester.
Normal At the normal temperature (10°C ~ 30°C)
Abnormal , open or short
Measure the voltage between motor wires with a tester.
Normal At the normal temperature (10˚C ~ 30˚C)
SH09BWHX only (AC Motor)
Abnormal , open or short
Measure the resistance between the red wire and each terminal wire with a tester.
Normal About 300 at the normal temperature (20˚C ~ 30˚C)
Abnormal , open or short
DiagnosisPart
Ambient temperature 15°C20°C25°C30°C35°C40°C
Resistance of
14.68 12.09 10 8.31 6.94 5.83
thermistor[K]
Ambient temperature 0°C10°C20°C30°C40°C50°C
Resistance of
553 362 242 166 165 82
thermistor[K]
Compare terminal Resistance() Remark
Yellow, Blue 460±10 Main
Yellow, Red 314±10% Sub
Compare terminal Resistance() Remark
Black, Red 255±10% Main
Black, Yellow 415±10% Sub