Samsung AM18A1E09 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro ne Samsung AM18A1E09. Samsung AM18A1E09 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 24
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
OWNERS INSTRUCTIONS
MANUAL DE INSTRUCCIONES
ISTRUZIONI PER LUSO
MANUAL DE INSTRUÇÕES
MANUEL DUTILISATION
GEBRAUCHSANWEISUNG
MULTI-SPLIT TYPE ROOM AIR CONDITIONER (Cool)
ACONDICIONADOR DE AIRE DOMÉSTICO SISTEMA MULTI SPLIT
(Refrigeración)
CONDIZIONATORE DARIA PER PIÙ AMBIENTI AD UNITÀ SEPARATE (Raffreddamento)
AR CONDICIONADO MULTI SPLIT (Refrigeração)
CLIMATISEUR DE TYPE MULTIPLE (Refroidissement)
RAUMKLIMAGERÄT IN MEHRFACH GETEILTER AUSFÜHRUNG (Kühlen)
ENGLISH
ESPAÑOL
ITALIANO
PORTUGUÉS
FRANÇAIS
DEUTSCH
ESIPFDDB68-30973A(4)
AM14A1(B1)E07
AM18A1(B1)E09
AM18A1(B1)B09
AM19A1(B1)E07
AM19A1(B1)E12
AM20A1(B1)E06
AM20A1(B1)E09
AM24A1(B1)E12
AM26A1(B1)B13
MC07ZV-14
MC09ZV-18
MC07ZV-19
MC12ZV-19
MC12ZV-24
Indoor Unit
Outdoor Unit
UM14A1(B1)E2
UM18A1(B1)E2
UM18A1(B1)B2
UM19A1(B1)E2
UM20A1(B1)E3
UM24A1(B1)E2
UM26A1(B1)B2
XMC14ZV
XMC18ZV
XMC19ZV
XMC24ZV
Zobrazit stránku 0
1 2 3 4 5 6 ... 23 24

Shrnutí obsahu

Strany 1 - Outdoor Unit

OWNER’S INSTRUCTIONSMANUAL DE INSTRUCCIONESISTRUZIONI PER L’USOMANUAL DE INSTRUÇÕESMANUEL D’UTILISATIONGEBRAUCHSANWEISUNGMULTI-SPLIT TYPE ROOM AIR CON

Strany 2 - Safety Precautions

You must select the Cool mode if you wish to adjust the:◆ Cooling temperature◆ Fan speed when cooling1 If necessary, press the (On/Off) button.Re

Strany 3 - Contents

E-11Changing the Room Temperature QuicklyMODETURBOOFFThe Turbo cooling function is used to cool your room as quickly as possible.Example:You have just

Strany 4 - View of the Outdoor Unit

Removing Excess HumidityMODETURBOOFFMODETURBOOFFMODETURBOOFFIf the atmosphere in your room is very humid or damp, you canremove excess humidity withou

Strany 5

E-13Airing Your RoomMODETURBOOFFMODETURBOOFFIf the atmosphere in your room is stale, you can air the room usingthe Fan feature.1 If necessary, press t

Strany 6 - Getting Started

Adjusting the Air Flow Direction VerticallyDepending on the position of the indoor unit on the wall of yourroom, you can adjust the position of the ou

Strany 7

E-15Switching the Unit On and Off Automatically (On/Off Timer)MODETURBOOFFYou can set the timer to switch the air conditioner on and/or offautomatical

Strany 8 - Setting the Time

Setting the Sleep TimerMODETURBOOFFThe Sleep Timer can be used when you are cooling your room toswitch the air conditioner off automatically after a p

Strany 9

E-17Cancelling the On/Off TimerMODETURBOOFFIf you no longer wish to use the On/Off Timer that you have set, youcan cancel it at any time.1 To cancel t

Strany 10 - Cooling Your Room

Operating RecommendationTemperature and Humidity RangesHere is a recommendation that you should follow when using yourair conditioner.Topic Recommenda

Strany 11

Cleaning Your Air ConditionerTo get the best possible use out of your air conditioner, you mustclean it regularly to remove the dust that accumulates

Strany 12 - Removing Excess Humidity

Safety PrecautionsThe following safety precautions must be taken when using your air conditioner.1 Make sure that the indoor unit is correctly ventila

Strany 13 - Airing Your Room

Explanation/Solution◆ Check that the breaker used for the air conditioner is switched on.◆ Check that the OPERATION indicator on the indoor unit is on

Strany 14

Operating Your Air Conditioner Without the Remote ControlYour air conditioner can be operated directly from the indoor unit ifthe remote control is lo

Strany 15 - IMPORTANTIM

Installing a Filter (Option)The air conditioner can be fitted with a deodorizing and Bio-Purefilter to remove minute dust particles or odours. The ser

Strany 16 - Setting the Quick Timer

Technical SpecificationsE-23ENGLISHAM14A1(B1)E07AM18A1(B1)E09AM19A1(B1)E07AM19A1(B1)E12AM20A1(B1)E06AM20A1(B1)E09AM24A1(B1)E12MC07ZV-14MC09ZV-18MC07ZV

Strany 17 - Cancelling the On/Off Timer

ELECTRONICSPrinted in KoreaTHIS AIR CONDITIONER IS MANUFACTURED BY:ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR:QUESTO CONDIZIONATORE D’ARIA È PRODOT

Strany 18 - Operating Recommendation

Contents◆ PREPARINGYOUR AIR CONDITIONER Safety Precautions ... 2

Strany 19 - Cleaning Your Air Conditioner

View of the Indoor UnitOPERATIONTURBOFANTIMERON/OFF switch(operation without remote control)Air Filter(under the grille)TIMER indicator- YELLOWOPERAT

Strany 20 - Solving Common Problems

Remote control - Buttons and DisplayE-5MODETURBOOFFOperating mode(AUTO, COOL, DRY, FAN)Turbo modeSleep modeFan speed(AUTO, LOW, MEDIUM, HIGH)Time/Time

Strany 21

Getting StartedYou have just purchased a multi-split type room air conditioner and it has been installedby your installation specialist.Your Owner’s I

Strany 22 - Installing a Filter (Option)

Installing the Remote Control Holder on the WallThe remote control is supplied with a plastic holder that can be fittedto the wall to hold the remote

Strany 23 - Technical Specifications

Setting the TimeE-8Your air conditioner contains a clock used to start and stop the unitautomatically at a given time.You must set the time when you:◆

Strany 24 - ELECTRONICS

You can start the air conditioner in Automatic mode from yourremote control. In the Automatic mode, the standard temperatureand the optimum fan speed

Komentáře k této Příručce

Žádné komentáře