Indoor UnitsIndoor UnitsSAMSUNG DVM Air ConditionerDVM PLUS III2010North America for 60Hz
8 1Outdoor units1-3. Outdoor unit combinations1) Basic models 2) Combinations Classification Capacity (Ton) Capacity (HP) ModelSingle unit6 7.5 RVXVH
9 ProductsModel name2Indoor units2-1. Nomenclature ClassificationIndoor unit (R410A) AVX Classification by product groupCassette type CDuct type DW
10 Indoor units2-2. Line-upModel name (Notation)020 023 032 040 052 060 072 100 110 145MBH 6.0 7.5 9.5 12.0 18.0 20.0 24.0 30.0 36.0 48.0Slim 1 way
11 ProductsAccessories3Classification Product Model Image Application modelIntegrated management systemControllerDMS MIM-D00 DVM Series, FJM, CAC, E
12 3AccessoriesClassification FeatureModel Description Relevant unit RemarkY-jointMXJ-YA1509Below 51MBHDVM PLUS II, DVM PLUS IIIRequisiteMXJ-YA25125
13 Indoor unitsII. Indoor units1 Slim 1 way cassette ...152 Mini 4 way cassette...233
INDOOR UNITS14
15 Indoor units1-1. Specifications ... 161-2. Dimensional drawing ...
16 Slim 1 way cassette11-1. Specifications1) Technical specificationsModel AVXCSH023CE AVXCSH032CE AVXCSH040CEPower Supply Ø/ V/ Hz 1/ 208~230/ 60 1/
17 Indoor units1-2. Dimensional drawingUnit : mm(inch)123564Suspension bolts(M8~M10) X 4EA970(38-1/4)415(16-3/8)160(6-1/4) 50(1-15/16)280(11)85(3-3/8)
Indoor Units
18 Slim 1 way cassette11-3. PCB connector lay-out114 13 12 1119181716152 3 4 5 678910ACBNo. CN # COLOR FUNCTION1CN61 RedSliding Panel 1(Only for slidi
19 Indoor units1-4. Electrical wiring diagram519181731512413 6 14 78910161211
20 Slim 1 way cassette11-5. Sound pressure level1) Operation sound level2) NC curves(1) AVXCSH023CE (2) AVXCSH032CE(3) AVXCSH040CE1m(3.3ft)1m(3.3ft)M
21 Indoor units1-6. Temperature and air flow distribution 1) Cooling air velocity distributionFloor distanceCeiling height0.2m/s(0.66ft/s)0.2m/s(0.66
22 INDOOR UNITS
23 Indoor unitsIndoor Unit2-1. Specifications ... 242-2. Dimensional drawing ...
24 2Mini 4 way cassette2-1. Specifications1) Technical specificationsModel AVXCMH032CE AVXCMH040CE AVXCMH052CE AVXCMH060CEPower Supply Ø/ V/ Hz 1/ 208
25 Indoor units1234 4567Suspension bolts(M8~M10) X 4EA8590~610(23-1/4~24) Ceiling opening575(22-3/4)123(4-3/4)48(2)575(22-3/4)343(13-1/2)343(13-1/2)67
26 2Mini 4 way cassette2-3. PCB connector lay-outNo.S/WFUNCTION ON OFFCK1 External temperature sensor Not useUseK2 Centralized Controller Not useUseK3
27 Indoor units141151210 8 131116765243 92-4. Electrical wiring diagram
Indoor Units
28 2Mini 4 way cassette2-5. Sound pressure level1) Operation sound level2) NC curves(1) AVXCMH032E (2) AVXCMH040E(3) AVXCMH052E (4) AVXCMH060E1.5m(4
29 Indoor units2-6. Temperature and air flow distribution 1) Cooling air velocity distributionCeiling heightFloor distance3 m1 m2.5 m1.5 m 0 m 1.5m2.
30 Mini 4 way cassette21) Cooling air velocity distributionCeiling heightFloor distance3 m1 m2.5 m1.5 m 0 m 1.5m2.5 m(8.2 ft)(4.9 ft) (0 ft) (4.9 ft)(
31 Indoor units3-1. Specifications ... 323-2. Dimensional drawing ...
32 34 way cassette3-1. Specifications1) Technical specificationsModel AVXC4H052CE AVXC4H072CE AVXC4H100CE AVXC4H110CE AVXC4H145CEPower Supply Ø / V/ H
33 Indoor units3-2. Dimensional drawing1) AVXC4H052/072CE123445678Suspension bolts(M8~M10) X 4EA766(30-1/8)950(37-3/8)699(27-1/2)950(37-3/8)950(37-1/2
34 34 way cassetteNo. NameDescription30.0 MBH 36.0 MBH 48.0 MBH1Liquid pipe connection Ø9.52(3/8") Flare2Gas pipe connection Ø15.88(5/8") Fl
35 Indoor units1 2 3 456789101112131415161718A CB3-3. PCB connector lay-outNo. S/W FUNCTIONAMain Address Setting (00~63)BSW03 SW04 Address of Interf
36 34 way cassette3-4. Electrical wiring diagram313511516211810946714181712
37 Indoor units3-5. Sound pressure level1) Operation sound level2) NC curves(1) AVXC4H052CE (2) AVXC4H072CE (3) AVXC4H100CE (4) AVXC4H110CE (5) AVX
2 123Outdoor units Indoor units Accessories I. Products6911
38 34 way cassette3-6. Temperature and air flow distribution 1) Cooling air velocity distributionCeiling heightFloor distance4 m4 m3 m 1 m 0 m1 m3 m2
39 Indoor units1) Cooling air velocity distributionCeiling heightFloor distance4 m4 m3 m 1 m 0 m1 m3 m2 m2 m(13.1 ft)(13.1 ft)(9.8 ft) (3.3 ft) (0 ft)
INDOOR UNITS40
41 Indoor units Slim duct (AVXDSHTTTCT)44-1. Specifications ... 424-2. Dimension
42 4Slim duct4-1. Specifications1) Technical specificationsModel AVXDSH020CE AVXDSH032CE AVXDSH040CE AVXDSH052CEPower SupplyØ / V/ Hz1/ 208~230/ 60 1/
43 Indoor unitsModel AVXDSH072CE AVXDSH100CE AVXDSH110CE AVXDSH145CEPower SupplyØ / V/ Hz1/ 208~230/ 60 1/ 208~230/ 60 1/ 208~230/ 60 1/ 208~230/ 60Mo
44 4Slim duct4-2. Dimensional drawing1) AVXDSH020/032/040CE12345678Suspension bolts(M8~M10) X 4EADuct flange connection bolts(M4) X 22EASuctionDischar
45 Indoor units2) AVXC4H052/072CE61234578Suspension bolts(M8~M10) X 4EADuct flange connection bolts(M4) X 26EASuctionDischarge10(3/8)100(4)71(2-3/4)50
46 4Slim duct4-2. Dimensional drawing3) AVXC4H100/110/145CE1 2345786Suspenslon bolts(M8~M10) X 4EADuct flange connection bolts(M4) X 32EASuctionDischa
47 Indoor units4-3. PCB connector lay-out1) AVXDSH020/032/040/052/072CENo. CN # COLOR FUNCTION1CN51 Black Float Switch2CN41 White Room Sensor, Eva-In
3 Indoor unitsProducts1234567 Slim 1 way cassetteMini 4 way cassette4 way cassetteSlim ductMSP(Middle static pressure) ductNeo ForteVivaceII. Indoor u
48 4Slim duct4-3. PCB connector lay-out2) AVXDSH100/110/145CENo. CN # COLOR FUNCTION1CN51 Black Float Switch2CN41 White Room Sensor, Eva-In Sensor3CN4
49 Indoor units4-4. Electrical wiring diagram1) AVXDSH020/032/040/052/072CE813111456231712941016181517MICOM Download
50 4Slim duct4-4. Electrical wiring diagram2) AVXDSH100/110/145CE813111456231712 9 4 1016181517192021MICOM Download
51 Indoor units4-5. Sound pressure level1) Operation sound level These operation values were obtained in a dead room. Sound pressure level will vary
52 4Slim duct4-6. Recommended operation range Adjust option code according to the actual installation condition (external static pressure).(1) AVXDSH
53 Indoor units(7) AVXDSH110CE (8) AVXDSH145CE ESP = External Static Pressure The graphs display the available external static pressure range of
54 INDOOR UNITS
55 Indoor units MSP(Middle static pressure) duct (AVXDUHTTTCT)55-1. Specifications ...
56 5MSP(Middle static pressure) duct5-1. Specifications1) Technical specifications*1) Mode HP : Heat Pump, HR : Heat Recovery*2) Norminal cooli
57 Indoor units5-2. Dimensional drawing1) AVXDUH100/110CE12457863Suspension bolts(M8~M10) X 4EADuct flange connection bolts(M4) X 18EASuctionDischarge
DVM PLUS III4
58 5MSP(Middle static pressure) duct5-2. Dimensional drawing2) AVXDUH145CE61234578Suspension bolts(M8~M10) X 4EADuct flange connection bolts(M4) X 20E
59 Indoor units5-3. PCB connector lay-out1) AVXDUH100/110/145CE1 2 3 4 5 6 78910111213201419151716ACB18No. CN # COLOR FUNCTION1CN51 Black Float Switch
60 5MSP(Middle static pressure) duct5-4. Electrical wiring diagram1) AVXDUH100/110/145CE8131115562317129 410161814171920MICOM Download
61 Indoor units5-5. Sound pressure level1) Operation sound level2m(6.9ft)1m(3.3ft)DuctDuct1.5m(4.9ft)MicrophoneDischarge Suction These operation val
62 MSP(Middle static pressure) duct5-6. Recommended operation range(1) AVXDUH100CE (2) AVXDUH110CE (3) AVXDUH145CEL HStandard ESP AreaL HHigh ESP Area
63 Indoor units Neo Forte (AVXWNHTTTCT)66-1. Specifications ... 646-2. Dimension
64 6Neo Forte6-1. Specifications1) Technical specificationsModel AVXWNH020CE AVXWNH032CE AVXWNH040CE AVXWNH052CE AVXWNH060CEPower SupplyØ / V/ Hz1/ 20
65 Indoor units6-2. Dimensional drawing1) AVXWNH020/032/040CE123456285(11-1/4)825(32-1/2)189(7 1/2)Unit:mm(inch)No. NameDescription6.0 MBH 9.5 MBH 12.
66 6Neo Forte6-2. Dimensional drawing2) AVXWNH052/060CE123456298(11-3/4)1065(41-7/8)218(8-5/8)Unit : mm(inch)No. NameDescription18.0 MBH 20.0 MBH1Liqu
67 Indoor units6-3. PCB connector lay-out1 234567891516141013ABC1112Main PCB Sub PCBNo. S/W FUNCTION ON OFFCK1 External temperature sensor Not useUseK
5 ProductsI. Products1 Outdoor units ...62 Indoor units ...93
68 6Neo Forte144511121326789 1510316-4. Electrical wiring diagram
69 Indoor units6-5. Sound pressure level1) Operation sound level1m(3.3ft)1m(3.3ft)Microphone2) NC curves(1) AVXWNH020CE (2)AVXWNH032CE (3) AVXWNH040
70 6Neo Forte6-6. Temperature and air flow distribution 1) Cooling air velocity distributionCeiling heightFloor distance8 m3 m1 m0 m1 m 3 m 4 m5 m7 m
71 Indoor units1) Cooling air velocity distributionCeiling heightFloor distance8 m3 m1 m0 m1 m 3 m 4 m5 m7 m2(9.8 ft)(3.3 ft)(6.6 ft) m2 m6(26.2 ft)(0
72 INDOOR UNITS
73 Indoor units Vivace (AVXWVHTTTCT)77-1. Specifications ... 747-2. Dimensional
74 7Vivace7-1. Specifications1) Technical specificationsModel AVXWVH020CE AVXWVH032CE AVXWVH040CE AVXWVH052CE AVXWVH060CEPower SupplyØ / V/ Hz1/ 208~2
75 Indoor units7-2. Dimensional drawing1) AVXWVH020/032/040CE123456285(11-1/4)825(32-1/2)141(5-1/2)85(3-3/8)380(15)45(1-3/4)189(7-1/2)56(2-1/4)63(2-1/
76 7Vivace7-2. Dimensional drawing2) AVXWVH052/060CE123456298(11-3/4)1065(41-7/8)160(6-1/4)570(22-1/2)50(2)218(8-5/8)67(2-5/8)60(2-3/8)60(2-3/8)50(2)N
77 Indoor units7-3. PCB connector lay-out1 216171514ABC1312 34561178910Main PCB Sub PCBMain PCBNo. CN # COLOR FUNCTION1CN71WhiteFan Motor2CN71BlueAC 2
6 1Outdoor units1-1. Nomenclature ClassificationOutdoor unit (R410A) RVX Capacity*×1/10 HP(3 digits) TypeMini DVM MDVM PLUS IIIVDVM PLUS III HR Ai
78 7Vivace7-4. Electrical wiring diagram561316 10152789121411431
79 Indoor units7-5. Sound pressure level1) Operation sound level2) NC curves(1) AVXWVH020CE (2) AVXWVH032CE (3) AVXWVH040CENC 40NC 35NC 30NC 25NC 20
80 7Vivace7-6. Temperature and air flow distribution 1) Cooling air velocity distributionCeiling heightFloor distance8 m3 m1 m0 m1 m 3 m 4 m5 m7 m2(9
81 Indoor units1) Cooling air velocity distributionCeiling heightFloor distance8 m3 m1 m0 m1 m 3 m 4 m5 m7 m2(9.8 ft)(3.3 ft)(6.6 ft) m2 m6(26.2 ft)(0
Memo
DVMDVM Technical Data Book
Indoor UnitsIndoor Units2009.12 DB98-31306A(1) Specification may be subject to change without prior notice for the continuous product improvement.Sam
7 ProductsTON 6 8HP 7.5 10.0 Model Name RVXVHT075/100FETON 10HP 12.5Model Name RVXVHT125FETON 12 14 16HP 15.0 17.5 20.0 Model Name RVXVHT150/175/200F
Komentáře k této Příručce